OS26.60-P-0015-01A Disposing of Pressure Reservoir



OS26.60-P-0015-01A Disposing of pressure reservoir
- Transmission 716.6
- with CODE (424) Sequentronic (SEQ) manual transmission


Danger!
Risk of injury when drilling gas-filled assemblies or components (gas filling cannot ignite) Wear safety glasses and face mask.






1 Allow hydraulic fluid to drain from pressure reservoir.

Observe regulations governing disposal of hydraulic fluid.

2 Clamp pressure reservoir firmly in vise.
3 Drill pressure reservoir approx. 15 mm (dimension A) away from the weld seam with 2 mm dia. drill (the gas escapes).
4 Dispose of pressure reservoir.