AR01.10-P-0010-01TI Connect Compression Tester
AR01.10-P-0010-01TI Connect Compression Tester
001 589 76 21 00
Compression recorder
220 589 00 99 00
Electrical connection kit
1 Remove cover of left fuse and relay box in the engine compartment.
Installation: Check rubber seal in cover, replace if required.
2 Unlock plug (2) on driver-side SAM control unit with fuse and relay module (N10/1) and detach.
3 Fold out cover (3a).
4 Connect compression recorder (01) to connection (3) and connect up using the adapter line (11) from the electrical connection kit at socket "5" on the plug (2).