AR20.00-P-1142-06TI Bleed Cooling System
AR20.00-P-1142-06TI Bleed cooling system
1 Switch the vehicle heating to maximum heating capacity and allow the engine to warm up with average engine speed.
2 Top up the coolant continuously until the coolant level reaches the mark on the coolant expansion reservoir.
3 After a coolant temperature of about 60 to 70° C. close the filler hole on the coolant expansion reservoir with a cap.