[2] Check component B11/4 (Coolant temperature sensor).: Open circuit in wiring / Short circuit to ground
[2] Check component B11/4 (Coolant temperature sensor).: Open circuit in wiring / Short circuit to ground
Test 1: Check component B11/4 (Coolant temperature sensor).
1. Check component B11/4 (Coolant temperature sensor).
Check actual value B11/4 (Coolant temperature sensor).
Note
- If fault exists, vehicle continues operating with substitute value from the temperature model.
Test prerequisite
- Switch on ignition.
Status of relevant actual value:
- Coolant temperature:Warning! Communication with ECU required.
Specified value
- If the connection is unplugged at component B11/4 (Coolant temperature sensor), the value is approx. -40° C.
Question
- Is the actual value o.k.?
YES
The actual values are okay.Further procedure
- Test wiring and plug connections between control module N3/9 (CDI control unit) and B11/4 (Coolant temperature sensor) for Loose contact, repair or replace if necessary.
End of test
NO
Voltage supply of component B11/4 (Coolant temperature sensor)
Figure legend
- B11/4 (Coolant temperature sensor)
Special tool
- Adapter cable220 589 00 99 34
Test prerequisite
- Switch off ignition.
- Detach coupling at component B11/4 (Coolant temperature sensor).
- Connect adapter cable no. 220 589 00 99 34 to engine wiring harness B11/4 (Coolant temperature sensor).
- Measure direct voltage with multimeter between sockets (B11/4x1) 1 and (B11/4x1) 2
- Switch on ignition.
Specified value
- Voltage[4.6...5.1] V
Question
- Is the measurement value OK?
YES
Check internal resistance of component B11/4 (Coolant temperature sensor).
Figure legend
- B11/4 (Coolant temperature sensor)
Note
- If fault exists, vehicle continues operating with substitute value from the temperature model.
Test prerequisite
- The actual value is not o.k.
Test sequence
- Switch off ignition.
- Connect adapter cable no. 220 589 00 99 34 at component B11/4 (Coolant temperature sensor).
- Test resistance.
- Measure resistance with multimeter between sockets (B11/4) 1 and (B11/4) 2
Specified value
- Resistor[20° C]: [2945...3240]ohms
- Resistor[60° C]: [609...653]ohms
- Resistor[90° C]: [229...242]ohms
- Resistor[120° C]: [99...103]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.Further procedure
- Test signal line between components N3/9 (CDI control unit) and B11/4 (Coolant temperature sensor) for Open circuit.
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Replace component B11/4 (Coolant temperature sensor).
End of test
NO
The measurement value is not OK.Further procedure
- Test signal line between components N3/9 (CDI control unit) and B11/4 (Coolant temperature sensor) for Open circuit.
End of test