E2636


[1] Rail pressure monitoring via volume control valve: Rail pressure too low due to air forming in the system when the fuel tank is run empty

Test 1: Rail pressure monitoring via volume control valve

1. Rail pressure monitoring via volume control valve
Possible cause and remedy

- This fault results from the tank being run empty.
- Fuel tank level minimum: 5Liters
End of test