[4] Check component G2 (generator).: Communication fault
[4] Check component G2 (generator).: Communication fault
Test 1: G2 (generator)
Test 2: Alternator diagnosis
1. G2 (generator)
Possible cause and remedy
- The line between control unit N3/9 (CDI control unit) and component G2 (generator) has short circuit to ground or there is a communication error.
End of test
2. Alternator diagnosis
Possible cause and remedy
- Check electrical line between component N3/9 (CDI control unit) and component G2 (generator) for contact and routing and (or) line breaks.
- Test wiring from component N3/9 (CDI control unit) to component G2 (generator) with an ohmmeter for short circuit (positive or negative) and repair, if necessary.
Connect test wiring harness with socket box with component N3/9 (CDI control unit) not connected.Other possible cause of fault
- The alternator regulator is defective
End of test