Manufacturer Code Charts: 2060
[4] Check component G3/1 (O2 sensor downstream TWC).: Pump current Open circuit in wiring / Short circuit to positive
Test 1: Check component G3/1 (O2 sensor downstream TWC).
1. Check component G3/1 (O2 sensor downstream TWC).
Important note:Reset quantity mean value adaptation data after replacing the following components:(Control unit adaptations/Reset quantity mean value adaptation data.)
- G3/2 (O2 sensor upstream of KAT)
- G3/1 (O2 sensor downstream TWC)
- B2/6 (Left hot film mass air flow sensor)
- B2/7 (Right hot film mass air flow sensor)
- B4/6 (Rail pressure sensor)
- Air filter
Communication with ECU required