[2] Check component Y76y4 (Fuel injector cylinder 4).: Short circuit to ground
[2] Check component Y76y4 (Fuel injector cylinder 4).: Short circuit to ground
Test 1: Test cables
1. Test cables
Test 1.1: Y76 (Fuel injectors) Test cable for short circuit to ground.
1.1. Y76 (Fuel injectors) Test cable for short circuit to ground.
Special tools
- Test cable 271 589 00 63 00
- Socket box 129 589 00 21 00
Test procedure Y76y4 (Fuel injector cylinder 4)
- Switch off ignition.
- Connect 126-pole socket box at engine wiring harness.
- Measure direct voltage with multimeter between socket [1.27] 27 of the 126-pole socket box tester and ground
- Measure direct voltage with multimeter between socket [1.75] 75 of the 126-pole socket box tester and ground
Specified value:
- Voltage value < 1 V ?
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Test cables and connections, rectify any short circuit.
End of test