AR01.10-P-0010-01PR Connect Compression Tester
AR01.10-P-0010-01PR Connect compression tester
Special Tools:
Component Identification:
1 Open cover (1) of front backup fuse box (F32).
2 Connect clamp (3) on compression recorder on terminal (2) of front backup fuse box (F32).
Shown on model 203
Component Identification:
3 Remove cover on fuse box.
Installation: Check the rubber seal in the cover. Replace it if necessary. The cover must be seated in the groove at the rear.
4 Remove starter relay (N10/1kS) from relay position S.
Component Identification:
5 Insert adapter line (6) into relay position S.
Component Identification:
6 Link adapter cable (6) to the cable of the compression recorder (7).