AR42.50-P-0001-07MB Checking Motor-and-Pump Assembly Cycling Points
AR42.50-P-0001-07MB Checking Motor-and-Pump Assembly Cycling Points
-MODEL 220.175 /178
- with CODE (Z07) Top protection
-MODEL 463.236 /248
- with CODE (979) Special protection version
The ignition must be switched off.
1 Release pressure from booster circuit (depress brake pedal approximately 30 times).
2 Switch on the ignition and wait until the motor-and-pump assembly is deactivated.
Read the motor-and-pump assembly's pressure at deactivation from the pressure gauge.
If the pressure lies between 172 and 190 bar:
System OK.
Pressure less than 172 bar or greater than 190 bar:
Malfunction in motor-and-pump assembly.
3 Switch off ignition.
4 Depress brake pedal to reduce reservoir pressure to 138 - 144 bar.
5 Switch on ignition and note whether motor-and-pump assembly starts to run.
Motor-and-pump assembly starts: System OK.
Motor-and-pump assembly fails to start:
Malfunction in motor-and-pump assembly.
6 Switch off ignition.