AR42.50-P-0001-06MB Check Motor/Pump Unit Charging Time
AR42.50-P-0001-06MB Check Motor/Pump Unit Charging Time
-MODEL 220.175 /178
- with CODE (Z07) Top protection
-MODEL 463.236 /248
- with CODE (979) Special protection version
1 Switch off ignition and reduce pressure in booster circuit (while doing so press brake pedal approx. 30 times).
2 Switch on ignition and measure the time until the motor/pump unit is switched off.
Time between 40 and 70 s: System OK.
Time > 70 s: Motor/pump unit defective.
Time < 40 s: Brake booster hydraulic unit defective.
3 Switch off ignition.