P1911
The link between control module N15/5 (Electronic selector lever module (ESM [EWM])) and the shift gate illumination is interrupted.
Operation number of operation texts and work units or standard texts and flat rates:27-0641Important note
- The following test sequence must in all cases be continued.
Continue with button "F2"
Possible cause
- The connector for the shift gate illumination is not in place.
- Cable fault
Possible remedy
- Establish connection to shift gate.
- Check continuity of line from component N15/5 (Electronic selector lever module (ESM [EWM])) to the shift gate illumination against wiring diagram.
Continue with button "F2"
Question
- Was the cause of the fault localized and eliminated?
YES
Preconditions
- The cause of the fault was localized and eliminated.
NOTE
- Further measures are not necessary.
End of test
NO
Preconditions
- The cause of the fault was neither localized nor eliminated.
Possible cause
- Shift gate illumination defective
Possible remedy
- Replace shift gate illumination.
Continue with button "F2"
Question
- Was the cause of the fault localized and eliminated?
YES
Preconditions
- The cause of the fault was localized and eliminated.
NOTE
- Further measures are not necessary.
End of test
NO
Preconditions
- The cause of the fault was neither localized nor eliminated.
Possible cause
- Internal error in control unit N15/5 (Electronic selector lever module (ESM [EWM]))
Possible remedy
- Replace floor-mounted shift complete.
WARNING
- The work procedure prescribed in section 'Initial startup' must be followed in all cases.
End of test