Air Door Vacuum Solenoid Valve: Application and ID
The vacuum connection on the valve block (Y11) for the recirculated air vacuum element (connection 3) is no longer used. The recirculated air flap vacuum element (42) is actuated together with the left (43) and right (44) main vent flap vacuum elements.