DTC P0132
DTC: P0132 Oxygen sensor 1 (G3/2) circuit high voltageActivation requirement CHECK ENGINE lamp:
Two consecutive trips with fault.
Activation of CHECK ENGINE lamp:
At start of next trip.
Test to detect fault:
With the oxygen sensor control activated, the diagnostic module checks if approximately 1280 mV is exceeded for longer than approximately 2.5 seconds.