Shift Valve Housing & Accumulator Housing
1. Raise and support vehicle.2. Remove oil drain plug and drain transmission fluid.
3. Remove four oil pan retaining bolts, then the oil pan.
4. Move shifter to ``P'' position and remove shift valve housing retaining bolts. Note bolt size for installation reference.
5. Reverse procedure to install, noting the following:
a. Ensure that range selector valve engages in the driver.
b. Torque attaching bolts to specifications.