Remove/Install Blower Control Regulator
Repair NoteLocation Of Current Regulator N29:
To gain access to the current regulator, remove the blower motor with bracket and the mounting screws (arrows), pull up carefully on the housing and remove the blower control from the side.
Three nuts attach the current regulator to the heatsink. Prior to installation coat the heat sink-to-regulator contact surface with commercially available heat conducting paste.