Test Preparation
The vacuum test is subdivided into 5 test Circuits (A to E) If there is a certain fault (eg, footwell flaps fail to open), the corresponding circuit can be tested first.If a leak is suspected in the total vacuum system for automatic climate control, first perform test step "A" and then proceed through the test circuits one after the other until the faulty vacuum Circuit is localized.
PERMISSIBLE LEAKS
Vacuum Circuit [1][2] 30 mbar/min
Check Valve [3] 50 mbar/10 min
Remaining Components [3] 20 mbar/min
_____________________________
[1]: At 400 mbar vacuum
[2]: Without vacuum reservoir
[3]: At 300 mbar vacuum