AR54.21-P-0013-02X SCN Coding With SDflash Online
AR54.21-P-0013-02X SCN Coding With SDflash Online
The following work instructions describes the procedure for Online SCN coding with "SDflash".
"SDflash" is the product designation of the program for determining the SCN coding and parameterization data.
Prerequisite for Online SCN coding with "SDflash":
- Networked STAR DIAGNOSIS diagnosis system
- Access to "SDflash" with corresponding rights
Entry into the coding in the diagnosis assistant system (DAS)
1 Select menu item "control unit adaptations" or "initial startup". Continue with "F3".
2 Select the menu item "SCN coding" in the further program run. Continue with "F3".
The program run may differ depending on the control unit.
3 Select menu item "Online (networked STAR DIAGNOSIS device)". Continue with "F3".
4 Confirm note on sequence of SCN coding with "F2".
5 Confirmation of the correct vehicle identification number with "F3".
A note on further action follows.
Coding steps in "SDflash Online"
6 Start Star Browser with "F5" button.
The program can also be opened via "Start/program/Star Browser".
If "SDflash" is already open, it is possible to change into the program with the button combination "ALT TAB" or via the task bar.
7 Logging on in "SDflash" with user name and password.
8 Call up "SDflash" with "Start" button.
9 Open vehicle data record with "F3".
If special equipment has been installed in or removed from the vehicle, the SA codes must be entered in the fields provided for this in "SDflash":
- "Positive SA codes": The SA codes entered here are fitted in the vehicle for the first time. They are taken into account for the generation of the SCN coding data
- "Negative SA codes": The SA codes entered here have currently been removed from the vehicle. They are no longer taken into account for the generation of SCN coding data
10 Use "F3" to start the request for forming the SCN coding data.
End of coding in DAS
11 Use "F3" to select menu item "Carry out SCN coding".
12 Confirm the vehicle identification number with "F3".
13 The control unit is coded after confirmation with "F3".
14 Fill in missing data in the order protocol and then print out with "F11" and enclose with the repair order.
The order protocol can also be stored in the STAR DIAGNOSIS device. After printing "F11" it is to be specified in the print dialog that printing to file should take place. This takes place by clicking on "print to file", selection of "printout of test step" and giving a file name.
In "StarUtilities" with the "StarPad" program the order log can be displayed and printed out under the item "log" -> "DAS log" -> printout of test step".
15 Continue with "F2".
The online SCN coding of the control unit is thus successfully completed.