GF80.50-D-2004H Trigger Anti-Theft Alarm System, Function
GF80.50-D-2004H Trigger Anti-Theft Alarm System, Function
- with CODE (FZ5) Anti-theft alarm system (ATA [EDW])
The anti-theft alarm system (ATA) triggers an alarm, if 2 subsequent status polls of the non-actuated state for the following switches are no longer recognized at an armed input:
- ATA engine hood switch, (S62) via discrete line
- Front passenger door CL rotary tumbler switch (M14/5s1), available from rear SAM control unit (N10) via controller area network, class B (interior compartment) (CAN B).
- Driver door CL rotary tumbler switch (M14/6s1), available from rear SAM control unit via CAN B.
- Rear-end door CL rotary tumbler switch (M14/7s1), available from SAM control unit via CAN B.
- Left door CL rotary tumbler switch (CREW CAB) (M14/8s1), on model 906.2, available from SAM control unit via CAN B.
- Right door CL rotary tumbler switch (CREW CAB) (M14/9s1), on model 906.2, available from SAM control unit via CAN B.
- Right sliding door CL rotary tumbler switch (M14/27s1), with code (T16) Right load compartment sliding door, available from SAM control unit via CAN B.
- Left sliding door CL rotary tumbler switch (M14/28s1), with code (T19) Left sliding door, available from SAM control unit via CAN B.
The acoustic alarm duration is limited to t = 0 to 60 s. This value can be set in 5 s steps.
Repetition alarm of ATA system
The alarm is repeated when the status of the one of the following components is changed again and can be triggered within one activation period of the corresponding components as often as follows:
- ATA hood switch via discrete line
1 to 10 times or unlimited (parameterizable)
- Passenger door CL rotary tumbler switch, available from rear SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Driver door CL rotary tumbler switch, available from rear SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Rear-end door CL rotary tumbler switch, available from SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Left door CL rotary tumbler switch CREW CAB, on model 906.2, available from SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Right door CL rotary tumbler switch CREW CAB, on model 906.2, available from SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Right sliding door CL rotary tumbler switch, with code (T16) Right load compartment sliding door, available from SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
- Left sliding door CL rotary tumbler switch, with code (T19) Left sliding door, available from SAM control unit via CAN B.
1 to 10 times or unlimited (parameterizable)
The acoustic alarm duration is limited to t = 0 to 60 s after the alarm timeout of t = 0 to 30 s.The alarm timeout can be set in 1 s increments and the acoustic alarm duration in 5 s increments.
Automatic ATA system alarm repetition (parameterizable)
An alarm is repeated automatically, when the acoustic alarm has stopped and the alarm timeout signals the status "OPEN" to one of the following components:
- ATA hood switch via discrete line.
- Passenger door CL rotary tumbler switch, available from rear SAM control unit via CAN B.
- driver door CL rotary tumbler switch, available from rear SAM control unit via CAN B.
- Rear-end door CL rotary tumbler switch, available from SAM control unit via CAN B.
- Left door CL rotary tumbler switch CREW CAB, on model 906.2, available from SAM control unit via CAN B.
- Right door CL rotary tumbler switch CREW CAB, on model 906.2, available from SAM control unit via CAN B.
- Right sliding door CL rotary tumbler switch, With code (T16) Right load compartment sliding door, available from SAM control unit via CAN B.
- Left sliding door CL rotary tumbler switch, With code (T19) Left sliding door, available from SAM control unit via CAN B.
After the acoustic alarm actuation alarm duration of t = 0 to 60 s and alarm timeout of t = 0 to 30 s, the acoustic alarm duration is limited to t = 300 s.The acoustic alarm actuation alarm duration can be set in 5 s increments and the alarm timeout in 1 s increments.
The acoustic alarm duration cannot be set in parameters.
Alarm interruption of ATA system
The alarm is interrupted when the "Unlock" transmit button on the transmitter key is pressed, simultaneously the ATA system is deactivated; this is indicated by the turn signal lamp flashing once and when the LED in the interior central locking button (N72/1s7) goes out.
The message "Unlock" from the EIS control unit (N73) is read by the OCP control unit (N70) via CAN B.
The message "EDW_ST (ATA status)" is transmitted by the OCP control unit to the UCP control unit (N72/1) via CAN B.