FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

AR54.21-D-2001-02E Carry Out Expert Coding



AR54.21-D-2001-02E Carry Out Expert Coding
- with CODE (ED5) Parameterizable module (PSM) Z�hler mit Schwellwertschalter
- with CODE (ED8) Preinstallation for parameterizable special module (PSM)


Function: Two lamps of a box body should be controlled by a button which is connected at input 01 (plug 2, pin 4).
The first time the button is pressed only lamp 1 is connected, the second time the button is pressed lamp 2 is also connected and the third time the button is pressed all the lamps are switched off.

Preconditions:
- The lamps are connected by relay.
- The relay is controlled by the output 01 (plug 2, pin 13) and by output 02 (plug 2, pin 16) on the parameterizable special module (PSM).

Activate SPS-function
1 Select menu item "Expert coding"
2 Select menu item "Logic functions"
3 Select menu item "Activation of SPS groups"
4 Set parameter "SPS group 1" on "ACTIVATED"
5 Conclude coding by pressing the F3 button

Configure threshold switch

6 Select menu item "Logic functions"
7 Select menu item "SPS group 1"
8 Select menu item "Threshold switch"
9 Set parameter "Threshold switch: input" on signal ID "301C"
10 Conclude coding by pressing the F3 button
11 Select menu item "Property parameterizing"
12 Set threshold A to "0"
13 Set threshold B to "1"
14 Set threshold C to "2"
15 Set operating mode to "Bargraph mode"
16 Conclude coding by pressing the F3 button

Configure counter

17 Select menu item "Logic functions"
18 Select menu item "SPS group 1"
19 Select menu item "Counter"
20 Set parameter "Counter: input 1" to signal-ID "1106"
21 Set parameter "Counter: input 2" to signal-ID "1001"
22 Set parameter "Counter: input 3" to signal-ID "1013"
23 Set parameter "Counter: input 4" to signal-ID "1000"
24 Conclude coding by pressing the F3 button
25 Select menu item "Property parameterizing"
26 Set counter reading after reset to "0"
27 Conclude coding by pressing the F3 button

Coding of outputs 01 and 02

28 Select menu item "Interfaces"
29 Select menu item "Outputs"
30 Set parameter "Output 01" to signal ID "1104"
31 Set parameter "Output 02" to signal ID "1105"
32 Conclude coding by pressing the F3 button