AR54.21-D-2001-02A Carry Out Expert Coding



AR54.21-D-2001-02A Carry Out Expert Coding
- with CODE (ED5) Parameterizable module (PSM) Ansteuerung der Fahrzeugfunktionen �ber diskrete Eing�nge


Function: When operating an alarm button, which is connected to input 01 (connector 2, pin 4), the following functions should be triggered and not be able to be interrupted via the "flasher" button or the rotary light switch:
- Synchronous flashing of high beam and front fog lamp
- Hazard warning flashing
- Audible warning device

Parameterize input 01 as "capable of waking"
1 Select menu item "Expert coding"
2 Select menu item "Interfaces"
3 Select menu item "Discrete inputs"
4 Select menu item "Property parameterizing"
5 Set parameter "Input 01 capable of waking" to "YES"
6 Conclude coding by pressing the F3 button

Parameterize high beam, front fog lamp, flasher and signaling horn

7 Select menu item "Interfaces"
8 Select menu item "Signals on interior CAN bus"
9 Select menu item "Alarm function"
10 Select menu item "Signal settings"
11 Set parameter "Switch on front fog lamp" to signal ID "1013"
12 Set parameter "Switch on high beam" to signal ID "1013"
13 Set parameter "Synchronous flashing" to signal ID "1001"
14 Set parameter "Flasher" to signal ID "1013"
15 Set parameter "Signaling horn" to signal ID "1013"
16 Conclude coding by pressing the F3 button
17 Select menu item "Interfaces"
18 Select menu item "Signals on interior CAN bus"
19 Select menu item "Alarm function"
20 Select menu item "Property parameterizing"
21 Adjust duration of light phases, dark phases
22 Adjust on time, off time of signaling horn