Battery: Description and Operation
AH54.10-P-0002-01A Notes On AGM Battery
As of Autumn 2000 new batteries with AGM technology will be used.
The external differentiation features between these batteries and conventional batteries are:
- Black housing
- VRLA battery labeling
- Non-detachable covers (A)
AGM battery structure
Instead of the acid in a conventional battery, a conductive fabric (bonded fiber) (V) is used.
Special properties:
- High cycle strength (long service life)
- Improved cold starting characteristics
- No escaping acid if housing damaged
- Improved deep-discharge resistance
- Absolutely maintenance-free
Distinguishing features
- No stop plugs
- No acid level markings
- No externally vented stop plugs
- Information plate on the battery
If the battery is replaced, the vent hose with an elbow to one side of the battery and the stop plugs on the other side of the battery must be pressed in.