Condenser HVAC: Service and Repair
AZ83.30-D-0001-19A Retrofit Condenser With Drier
- MODEL 906.### #N as of 315764, 906.### #S as of 105757, 906.### #A as of 961268
1 Position refrigerant pressure sensor (B12) with sealing ring (3) onto condenser connector (1) and screw into place .
2 Release radiator (2) from upper clamp connections and push to the rear.
3 Position condenser (1) onto radiator frame fixtures and push down.
4 Insert radiator (2) back into upper clamp connections.