Installation
1UR-FSE ENGINE CONTROL SYSTEM: MASS AIR FLOW METER: INSTALLATION
1. INSTALL MASS AIR FLOW METER SUB-ASSEMBLY (for Bank 1)
(a) Install the MAF meter with the 2 screws.
Torque : 1.0 Nm (10 kgf-cm, 9 in-lbf)
NOTICE:
* If the screw is tightened excessively, the screw hole may be damaged.
* Make sure the O-ring is not pinched.
2. INSTALL MASS AIR FLOW METER SUB-ASSEMBLY (for Bank 2)
(a) Install the MAF meter with the 2 screws.
Torque : 1.0 Nm (10 kgf-cm, 9 in-lbf)
NOTICE:
* If the screw is tightened excessively, the screw hole may be damaged.
* Make sure the O-ring is not pinched.
3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY LH
(a) Install the air cleaner cap to the air cleaner case with the 2 clips.
for hose clamp - Torque : 3.8 Nm (39 kgf-cm, 34 in-lbf)
HINT
Insert the protrusion of the air cleaner hose into the hole of the hose clamp.
4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY RH
(a) Install the air cleaner cap to the air cleaner case with the 2 clips.
for hose clamp - Torque : 3.8 Nm (39 kgf-cm, 34 in-lbf)
HINT
Insert the protrusion of the air cleaner hose into the hole of the hose clamp.
5. INSTALL V-BANK COVER SUB-ASSEMBLY Installation
6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
7. INSTALL COWL TOP VENTILATOR LOUVER RH Installation
8. PERFORM INITIALIZATION
(a) Perform initialization Repair Instruction - Initialization.
NOTICE:
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.