Installation
4GR-FSE ENGINE CONTROL SYSTEM: VVT SENSOR: INSTALLATION
1. INSTALL VVT SENSOR (for Exhaust Side of Bank 2)
(a) Install the sensor with the bolt.
Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)
(b) Connect the sensor connector.
2. INSTALL VVT SENSOR (for Intake Side of Bank 2)
(a) Install the sensor with the bolt.
Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)
(b) Connect the sensor connector.
3. INSTALL VVT SENSOR (for Exhaust Side of Bank 1)
(a) Install the sensor with the bolt.
Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)
(b) Connect the sensor connector.
4. INSTALL VVT SENSOR (for Intake Side of Bank 1)
(a) Install the sensor with the bolt.
Torque : 10 Nm (102 kgf-cm, 7 ft-lbf)
(b) Connect the sensor connector.
5. INSTALL V-BANK COVER SUB-ASSEMBLY Installation