Removal
P410 HYBRID TRANSMISSION / TRANSAXLE: GENERATOR CABLE: REMOVAL
1. PRECAUTION
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Service Precautions.
2. REMOVE REAR NO. 2 FLOOR BOARD Removal
3. REMOVE REAR DECK FLOOR BOX Removal
4. REMOVE REAR NO. 3 FLOOR BOARD Removal
5. REMOVE DECK FLOOR BOX RH Removal
6. REMOVE REAR FLOOR BOARD UPPER NO. 3 PLATE Removal
7. DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.
8. REMOVE SERVICE PLUG GRIP Removal
9. REMOVE FRONT LOWER BUMPER ABSORBER
10. REMOVE NO. 1 ENGINE UNDER COVER
11. DRAIN COOLANT (for Engine) Coolant (For Engine)
12. DRAIN COOLANT (for Inverter) Coolant (For Inverter)
13. REMOVE INVERTER COVER ASSEMBLY LH (w/ Cover) Removal
14. REMOVE RADIATOR SUPPORT OPENING COVER Removal
15. REMOVE NO. 1 INVERTER BRACKET Removal
16. DISCONNECT ENGINE ROOM MAIN WIRE Removal
17. REMOVE INVERTER COVER Removal
18. CHECK TERMINAL VOLTAGE Removal
19. DISCONNECT FRAME WIRE Removal
20. DISCONNECT GENERATOR CABLE Removal
21. DISCONNECT MOTOR CABLE Removal
22. DISCONNECT NO. 2 ENGINE WIRE Removal
23. INSTALL INVERTER COVER Removal
24. DISCONNECT NO. 2 ENGINE ROOM WIRE Removal
25. DISCONNECT WATER HOSE Removal
26. REMOVE INVERTER WITH CONVERTER ASSEMBLY Removal
27. REMOVE INVERTER RESERVE TANK ASSEMBLY Removal
28. REMOVE INVERTER TRAY BRACKET Removal
29. REMOVE RADIATOR PIPE
(a) Disconnect the 3 clamps, No. 1 radiator hose, No. 4 water by-pass hose and No. 3 radiator hose.
(b) Remove the 2 bolts and radiator pipe.
30. REMOVE GENERATOR CABLE
NOTICE:
Wear insulated gloves.
(a) Disconnect the generator cable clamp from the motor cable bracket.
(b) Remove the 3 bolts and slide the generator cable connector shell back.
(c) Disengage the 2 claws to remove the terminal cap.
(d) Remove the 3 bolts and generator cable from the hybrid transaxle assembly.