Installation
HEATING / AIR CONDITIONING: AIR CONDITIONING PRESSURE SENSOR: INSTALLATION
1. INSTALL AIR CONDITIONING PRESSURE SENSOR
(a) Apply a sufficient amount of compressor oil to a new air conditioning pressure sensor.
Compressor oil:
ND-OIL 11 or equivalent
NOTICE:
* Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign matter.
* Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.
(b) Install the new air conditioning pressure sensor.
Torque : 11 Nm (110 kgf-cm, 8 ft-lbf)
NOTICE:
* Do not deform the piping.
* Make sure to confirm that the piping does not disengage from the plastic clamp.
(c) Connect the connector.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.
3. INSTALL REAR FLOOR BOARD UPPER NO. 3 PLATE Installation
4. INSTALL DECK FLOOR BOX RH Installation
5. INSTALL REAR NO. 3 FLOOR BOARD Installation
6. INSTALL REAR DECK FLOOR BOX Installation
7. INSTALL REAR NO. 2 FLOOR BOARD Installation
8. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT Service and Repair
9. WARM UP COMPRESSOR Service and Repair
10. INSPECT FOR REFRIGERANT LEAK Service and Repair