Solar Sensor: Testing and Inspection





AIR CONDITIONING: SOLAR SENSOR: ON-VEHICLE INSPECTION

1. CHECK AIR CONDITIONING SOLAR SENSOR

(a) Disconnect the A/C solar sensor connector.





(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:





(c) Measure the voltage according to the value(s) in the table below.

Standard voltage:





2. INSPECT SOLAR SENSOR

(a) Remove the A/C solar sensor with the connector still connected.





(b) Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.

(c) Measure the voltage according to the value(s) in the table below.

Standard voltage:





NOTICE:
The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and negative (-) lead to terminal 1 of the solar sensor.

HINT
* As the inspection light is moved away from the sensor, the voltage increases.