FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Shift Solenoid: Testing and Inspection





A761E AUTOMATIC TRANSMISSION: SHIFT SOLENOID VALVE: INSPECTION

1. INSPECT SHIFT SOLENOID VALVE SL1

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

2. INSPECT SHIFT SOLENOID VALVE S1

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

3. INSPECT SHIFT SOLENOID VALVE S2

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

4. INSPECT SHIFT SOLENOID VALVE S3

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

5. INSPECT SHIFT SOLENOID VALVE S4

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

6. INSPECT SHIFT SOLENOID VALVE SL2

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

7. INSPECT SHIFT SOLENOID VALVE SR

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

8. INSPECT SHIFT SOLENOID VALVE SLT

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 of the solenoid valve connector and the negative (-) lead to terminal 1, and check the operation of the valve.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

9. INSPECT SHIFT SOLENOID VALVE SLU

(a) Measure the resistance of the valve.





Standard resistance:





(b) Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.

NOTICE:
While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.