Inspection
3UZ-FE EMISSION CONTROL: PURGE VALVE: INSPECTION
INSPECTION
1. INSPECT PURGE VSV
(a) Measure the resistance of the purge VSV.
Standard resistance:
If the result is not as specified, replace the purge VSV.
(b) Check the operation of the purge VSV.
(1) Check that air does not flow from port E to port F.
(2) Apply battery voltage across the terminals.
(3) Check that air flows from port E to port F.
If the result is not as specified, replace the purge VSV.