Removal
1UR-FSE ENGINE CONTROL SYSTEM: VVT SENSOR: REMOVAL
REMOVAL
1. REMOVE V-BANK COVER SUB-ASSEMBLY Removal
2. REMOVE AIR CLEANER INLET COVER SUB-ASSEMBLY Removal
3. REMOVE NO. 1 AIR CLEANER INLET Removal
4. REMOVE AIR CLEANER ASSEMBLY LH
(a) Disconnect the MAF meter connector.
(b) Remove the 2 clips, hose clamp and air cleaner cap.
(c) Remove the element from the air cleaner case.
(d) Remove the 2 nuts, clip and air cleaner case.
5. REMOVE AIR CLEANER ASSEMBLY
(a) Disconnect the MAF meter connector.
(b) Remove the 2 clips, hose clamp and air cleaner cap.
(c) Remove the element from the air cleaner case.
(d) Remove the 2 nuts, clip and air cleaner case.
6. REMOVE VVT SENSOR
(a) Disconnect the 4 VVT sensors.
(b) Remove the 4 bolts and 4 VVT sensors.