Removal
1UR-FSE COOLING: COOLING FAN MOTOR: REMOVAL
REMOVAL
1. REMOVE COWL TOP VENTILATOR LOUVER RH Removal
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
NOTE: After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory and settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery terminal.
3. REMOVE V-BANK COVER SUB-ASSEMBLY Removal
4. REMOVE AIR CLEANER INLET COVER Removal
5. REMOVE NO. 1 AIR CLEANER INLET Removal
6. REMOVE ENGINE ROOM SIDE COVER RH Removal
7. REMOVE ENGINE ROOM SIDE COVER LH Removal
8. REMOVE NO. 1 ENGINE UNDER COVER Service and Repair
9. DRAIN ENGINE COOLANT Service and Repair
10. DISCONNECT NO. 1 RADIATOR HOSE
11. DISCONNECT NO. 2 RADIATOR HOSE
12. REMOVE ECM OUTLET DUCT Removal
13. REMOVE RADIATOR RESERVOIR ASSEMBLY Removal
14. REMOVE FAN SHROUD WITH FAN AND MOTOR
(a) Disconnect the cooling fan ECU's connector.
(b) Using a clip remover, detach the 3 clamps.
(c) Detach the 3 claws, and then remove the fan shroud with fan and motor.