Variable Valve Timing Actuator Position Sensor: Service and Repair
REMOVAL1. REMOVE V-BANK COVER SUB-ASSEMBLY
2. REMOVE AIR CLEANER INLET COVER SUB-ASSEMBLY
3. REMOVE NO.1 AIR CLEANER INLET
4. REMOVE AIR CLEANER ASSEMBLY LH
a. Disconnect the MAF meter connector.
b. Remove the 2 clips, hose clamp and air cleaner cap.
c. Remove the element from the air cleaner case.
d. Remove the 2 nuts, clip and air cleaner case.
5. REMOVE AIR CLEANER ASSEMBLY
a. Disconnect the MAF meter connector.
b. Remove the 2 clips, hose clamp and air cleaner cap.
c. Remove the element from the air cleaner case.
d. Remove the 2 nuts, clip and air cleaner case.
6. REMOVE VVT SENSOR
a. Disconnect the 4 VVT sensors.
b. Remove the 4 bolts and 4 VVT sensors.
INSTALLATION
1. INSTALL VVT SENSOR
a. Install the 4 VVT sensors with the 4 bolts.
Torque:10 N.m (102 kgf.cm, 7 ft.lbf)
b. Connect the 4 VVT sensor connectors.
2. INSTALL AIR CLEANER ASSEMBLY
a. Install the air cleaner case with the 2 nuts and clip.
Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)
b. Install the element to the air cleaner case.
c. Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.
Torque: 3.8 N.m (38 kgf.cm, 34 in.lbf)
NOTE: Insert the protrusion of the air cleaner hose into the hole of the hose clamp.
HINT:
- The hose clamp can be tightened within the range of 2.0 N.m (20 kgf.cm, 18 in.lbf) to 5.5 N.m (56 kgf.cm, 49 in.lbf).
- When tightening the hose clamp, make sure the hose clamp's end is within the painted white line (width: 2 mm or 0.079 in.).
d. Install the air cleaner cap to the air cleaner case with the 2 clips.
e. Connect the MAF meter connector.
3. INSTALL AIR CLEANER ASSEMBLY LH
a. Install the air cleaner case with the 2 nuts and clip.
Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)
b. Install the element to the air cleaner case.
c. Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.
Torque: 3.8 N.m (38 kgf.cm, 34 in.lbf)
NOTE: Insert the protrusion of the air cleaner hose into the hole of the hose clamp.
HINT:
- The hose clamp can be tightened within the range of 2.0 N.m (20 kgf.cm, 18 in.lbf) to 5.5 N.m (56 kgf.cm, 49 in.lbf).
- When tightening the hose clamp, make sure the hose clamp's end is within the painted white line (width: 2 mm or 0.079 in.).
d. Install the air cleaner cap to the air cleaner case with the 2 clips.
e. Connect the MAF meter connector.
4. INSTALL NO. 1 AIR CLEANER INLET
5. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY
6. INSTALL V-BANK COVER SUB-ASSEMBLY