B1423
DTC B1423/23 Pressure Sensor CircuitDESCRIPTION
DTC Detection Condition:
This DTC is output when refrigerant pressure is extremely low (0.19 MPa (2.0 kgf/sq.cm, 28 psi) or less) or extremely high (3.14 MPa (32.0 kgf/sq.cm, 455 psi) or more). The pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs the refrigerant pressure signal to the A/C amplifier. The A/C amplifier converts the signals to pressure according to the sensor characteristics to control the compressor.
HINT: Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be output if there is no refrigerant in the cycle.
Wiring Diagram:
Step 1-2:
Step 2 (Continued):
Step 3-4:
Step 5:
INSPECTION PROCEDURE