Thermostat: Specifications
Valve opening temperature 80 to 84°C (176 to 183°F)If the valve opening temperature is not as specified, replace the water inlet sub-assembly with thermostat.
Valve lift 8.0 mm (0.315 inch) or more at 95°C (203°F).
If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.
Check that the valve is fully closed when the water inlet with thermostat is at low temperature (below 40°C (104°F)).