Canada - Starting System - Vehicle Start After Battery Deplete
BulletinTSB2125
Issue Date
June 02, 2005
Title
VEHICLE START AFTER BATTERY DEPLETION
Component
ENGINE ELECTRICAL
Models
'06 GS300 & GS430
INTRODUCTION:
In vehicles equipped with the push-button start function, the starting function may not be operational after recharging or while jump-starting a discharged battery. This condition is most common if battery voltage drops below 9 volts. The following procedure has been developed to address this condition.
APPLICABLE VEHICLES:
- 2006 model year GS300 and GS430 vehicles.
INITIALIZATION PROCEDURE:
1. Confirm that the DCC fuse is installed.
NOTE:
If the DCC fuse is not installed, please install it at this time.
2. Place the shift lever in the "P" position.
3. Open or close the driver's side door.
NOTE:
This will start an initialization process between the Steering Lock ECU and the Junction Block ECU.
4. Depress brake pedal.
5. Press the "START STOP" switch.
WARRANTY INFORMATION: