Blower Motor: Service and Repair
Blower Assy:
OVERHAUL
HINT: Observe Restraint Systems Service Precautions.
1. REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
2. REMOVE HEATER TO FOOT DUCT NO.1
3. REMOVE BLOWER ASSEMBLY
4. REMOVE AIR REFINER ELEMENT
5. REMOVE COWL WIRE NO.2
a. Remove the clamp and cowl wire No.2.
6. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY
a. Remove the 3 screws and recirculation damper servo sub-assembly.
7. REMOVE INSTRUMENT PANEL NO.3 WIRE
a. Disconnect the connectors, remove the 2 clamps and instrument panel No.3 wire.
8. REMOVE BLOWER MOTOR CONTROL
a. Remove the 2 screws and blower motor control.
9. REMOVE BLOWER W/FAN MOTOR SUB-ASSEMBLY
a. Remove the 3 screws and blower w/fan motor sub-assembly.
10. INSTALL BLOWER ASSEMBLY
11. INSTALL INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY