Fail-Safe Operation
FAIL-SAFE FUNCTIONWhen short circuit of the shock absorber control actuator is detected, the shock absorber control actuator located on the other side of the detected shock absorber is held at step 8. The shock absorber control actuator remains uninterrupted until the ignition switch becomes OFF.