Without Driving Position Memory
R4 REMOTE CONTROL MIRROR SW4 - GROUND : Approx. 12 volts with the ignition SW at ACC or ON position
7 - 8 : Continuity with the operation SW at DOWN or RIGHT position
4 - 7 : Continuity with the operation SW at UP or LEFT position
8 - GROUND : Always continuity