Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor Connector (Bank 1 Sensor 1) Location:
Heated Oxygen Sensor Connector (Bank 1 Sensor 2) Location:
COMPONENTS
INSPECTION
1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS (BANK 1,2 SENSOR 1)
a. Disconnect the oxygen sensor connectors.
b. Using an ohmmeter, measure the resistance between the terminals +B and HT
Resistance:
20°C (68°F) 11 - 16 ohms
800°C (1,472°F) 23 - 32 ohms
If the resistance is not as specified, replace the sensor.
c. Reconnect the oxygen sensor connectors.
2. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS (BANK 1,2 SENSOR 2)
a. Disconnect the oxygen sensor connectors.
b. Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance:
20°C (68°F) 11 - 16 ohms
800°C (1,472°F) 23 - 32 ohms
If the resistance is not as specified, replace the sensor.
c. Reconnect the oxygen sensor connectors.
3. INSPECT OPERATION OF HEATED OXYGEN SENSORS