On-Vehicle Inspection
INSPECT OIL CONTROL VALVE RESISTANCEa. Remove the V-bank cover.
b. Disconnect the oil control valve connector.
c. Using an ohmmeter, measure the resistance between the terminals.
Resistance: 6.9 - 7.9 Ohms at 20 °C (68 °F)
If the resistance is not as specified, replace the valve.
d. Reconnect the oil control valve connector.
e. Reinstall the V-bank cover.