Accelerator Pedal Position Sensor: Testing and Inspection
INSPECTION
INSPECT ACCELERATOR PEDAL POSITION SENSOR
(a) Disconnect the accelerator position sensor connector.
(b) Using an ohmmeter, measure the resistance between terminals VC and E2.
Resistance: 1.64 - 3.28 k ohms at 20°C (68°F)
If the resistance is not as specified, replace the accelerator pedal position sensor.
(c) Reconnect the accelerator pedal position sensor connector.