Main Relay
INSPECTION1. Remove relay box cover.
2. Remove radiator fan main relay. (Marking: RAD FAN MAIN)
3. Inspect radiator fan main relay.
a. Inspect the relay continuity
1) Using an ohmmeter, check that there is continuity between terminals 3 and 5.
If there is no continuity' replace the relay.
2) Check that there is continuity between terminals 2 and 4.
If there is no continuity, replace the relay.
3) Check that there is no continuity between terminals 1 and 2.
If there is continuity, replace the relay.
b. Inspect the relay operation
Apply battery positive voltage across terminals 3 and 5.
2) Using an ohmmeter, check that there is no continuity between terminals 2 and 4.
If there is continuity, replace the relay.
3) Check that there is continuity between terminals 1 and 2.
If there is no continuity, replace the relay.
4. Reinstall radiator fan main relay.
5. Reinstall relay box cover.