Heated Glass Element
Defogger WiresVoltage Note: Wind a piece of tin foil around the top of the negative probe and press the foil against the wire with your fingers. | Condition |
5 Volts (V) | OK |
10 Volts (V) | Broken wire |
0 Volts (V) | Broken wire |
Voltage Note: Wind a piece of tin foil around the top of the negative probe and press the foil against the wire with your fingers. | Condition |
5 Volts (V) | OK |
10 Volts (V) | Broken wire |
0 Volts (V) | Broken wire |