Air Flow Meter/Sensor: Service and Repair
1. REMOVE AIR CLEANER HOSE
- Disconnect the PCV hose.
- Loosen the 2 hose clamps, and remove the air cleaner hose.
2. REMOVE MAF METER
- Disconnect the MAF meter connector.
- Remove the 2 bolts and MAF meter.
Torque: 6.9 N.m (70 kgf.cm, 61 in.lb.)
MAF METER INSTALLATION
INSTALLATION HINT: Installation is in the reverse order of removal.