Ignition Cable: Testing and Inspection
INSPECT HIGH-TENSION CORD RESISTANCE
- Using an ohmmeter, measure the resistance.
Maximum resistance: 26 K ohms per cord
- If the resistance is greater than maximum, check the terminals.
- If necessary, replace the high-tension cord.