Fuel Pump Relay: Testing and Inspection
1. REMOVE CIRCUIT OPENING RELAY
2. INSPECT CIRCUIT OPENING RELAY
- Inspect relay continuity
- Using an ohmmeter, check that there is continuity between terminals ST and E1.
- Check that there is continuity between terminals +B and FC.
- Check that there is no continuity between terminals +B and FP.
- If there is continuity, replace the relay.
- Inspect relay operation
- Apply battery positive voltage across terminals ST and E1.
- Using an ohmmeter, check that there is continuity between terminals +B and FP.
- If there is no continuity, replace the relay.
3. REINSTALL CIRCUIT OPENING RELAY