Without Driving Position Memory
R17 REMOTE CONTROL MIRROR SW12-Ground: Approx. 12 Volts with Ignition SW at ACC or ON position
11-8: Continuity with operation SW at LEFT or UP position
3-11: Continuity with operation SW at RIGHT or DOWN position
8-Ground: Always continuity