Power Tilt and Power Telescopic (Without Memory)
C10 TILT AND TELESCOPIC UNIT (COMB. SW)
9-4: Approx. 160 Ohms with telescopic long operation
Approx. 360 Ohms with tilt up operation
Approx. 790 Ohms with telescopic short operation
Approx. 1.99 K Ohms with tilt down operation
T10 TILT POSITION SENSOR
1-2: Approx. 5 K Ohms
T13 TELESCOPIC POSITION SENSOR AND MOTOR
1-2: Approx. 5 K Ohms
U 1 UNLOCK WARNING SW
2-1: Closed with ignition key in cylinder
P 1 A/T INDICATOR SW (PARK/NEUTRAL POSITION SW)
4-7: Closed with shift lever at P position
T 8-B, T 9-A TILT AND TELESCOPIC ECU
B-4-GROUND: Always Approx. 12 Volts
A-10-GROUND: Approx. 12 Volts with ignition SW at ON or ST position
A-18-GROUND: Always Approx. 12 Volts
A-11-GROUND: Approx. 12 Volts with ignition SW at ON or ST position and shift lever at "P" position
A-8-GROUND: Continuous with ignition key in cylinder
A-7-GROUND: Always continuous
B-10-GROUND: Approx. 12 Volts with tilt up operation
B-3-GROUND: Approx. 12 Volts with tilt down operation
B-2-GROUND: Approx. 12 Volts with telescopic short operation
B-11-GROUND: Approx. 12 Volts with telescopic long operation
B-7-GROUND: Always continuous