Air Flow Meter/Sensor

VOLUME AIR FLOW (VAF) METER
Resistance between terminals THA - E2
Temperature Resistance
-20°C (-4°F) 10 - 20 ohms
0°C (32°F) 4 - 7 ohms
20°C (68°F) 2 - 3 kohms
40°C (104°F) 0.9 - 1.3 kohms
60°C (140°F) 0.4 - 0.7 kohms